42 research outputs found

    Meniscal T1rho and T2 measured with 3.0T MRI increases directly after running a marathon

    Get PDF
    PURPOSE: To prospectively evaluate changes in T1rho and T2 relaxation time in the meniscus using 3.0Β T MRI in asymptomatic knees of marathon runners and to compare these findings with those of age-matched healthy subjects. MATERIAL AND METHODS: Thirteen marathon runners underwent 3.0Β T MRI including T1rho and T2 mapping sequences before, 48-72Β h after, and 3Β months after competition. Ten controls were examined at baseline and after 3Β months. All images were analyzed by two musculoskeletal radiologists identifying and grading cartilage, meniscal, ligamentous. and other knee abnormalities with WORMS scores. Meniscal segmentation was performed to generate T1rho and T2 maps in six compartments. RESULTS: No differences in morphological knee abnormalities were found before and after the marathon. However, all marathon runners showed a significant increase in T1rho and T2 values after competition in all meniscus compartments (p < 0.0001), which may indicate changes in the biochemical composition of meniscal tissue. While T2 values decreased after 3Β months T1rho values remained at a high level, indicating persisting changes in the meniscal matrix composition after a marathon. CONCLUSION: T2 values in menisci have the potential to be used as biomarkers for identifying reversible meniscus matrix changes indicating potential tissue damage. T1rho values need further study, but may be a valuable marker for diagnosing early, degenerative changes in the menisci following exercise

    Characterization of Human Osteoarthritic Cartilage Using Optical and Magnetic Resonance Imaging

    Get PDF
    Purpose: Osteoarthritis (OA) is a degenerative disease starting with key molecular events that ultimately lead to the breakdown of the cartilage. The purpose of this study is to use two imaging methods that are sensitive to molecular and macromolecular changes in OA to better characterize the disease process in human osteoarthritic cartilage. Procedures: Human femoral condyles were collected from patients diagnosed with severe OA during total knee replacement surgeries. T1ρ and T2 magnetic resonance measurements were obtained using a 3-Tesla whole body scanner to assess macromolecular changes in the damaged cartilage matrix. Optical imaging was performed on specimens treated with MMPSense 680 to assess the matrix metalloproteinase (MMP) activity. A linear regression model was used to assess the correlation of MMP optical data with T 1ρ magnetic resonance (MR) measurements. Slices from a representative specimen were removed from regions with high and low optical signals for subsequent histological analysis. Results: All specimens exhibit high T1ρ and T2 measurements in the range of 48–75 ms and 36– 69 ms, respectively. They also show intense photon signals (0.376 to 7.89Γ—10 βˆ’4 cm 2) from th

    Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0Β T with respect to osteoarthritis-induced changes at the knee joint

    Get PDF
    The objectives of the study were to optimize three cartilage-dedicated sequences for in vivo knee imaging at 7.0Β T ultra-high-field (UHF) magnetic resonance imaging (MRI) and to compare imaging performance and diagnostic confidence concerning osteoarthritis (OA)-induced changes at 7.0 and 3.0Β T MRI. Optimized MRI sequences for cartilage imaging at 3.0Β T were tailored for 7.0Β T: an intermediate-weighted fast spin-echo (IM-w FSE), a fast imaging employing steady-state acquisition (FIESTA) and a T1-weighted 3D high-spatial-resolution volumetric fat-suppressed spoiled gradient-echo (SPGR) sequence. Three healthy subjects and seven patients with mild OA were examined. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diagnostic confidence in assessing cartilage abnormalities, and image quality were determined. Abnormalities were assessed with the whole organ magnetic resonance imaging score (WORMS). Focal cartilage lesions and bone marrow edema pattern (BMEP) were also quantified. At 7.0Β T, SNR was increased (p < 0.05) for all sequences. For the IM-w FSE sequence, limitations with the specific absorption rate (SAR) required modifications of the scan parameters yielding an incomplete coverage of the knee joint, extensive artifacts, and a less effective fat saturation. CNR and image quality were increased (p < 0.05) for SPGR and FIESTA and decreased for IM-w FSE. Diagnostic confidence for cartilage lesions was highest (p < 0.05) for FIESTA at 7.0Β T. Evaluation of BMEP was decreased (p < 0.05) at 7.0Β T due to limited performance of IM-w FSE. Gradient echo-based pulse sequences like SPGR and FIESTA are well suited for imaging at UHF which may improve early detection of cartilage lesions. However, UHF IM-w FSE sequences are less feasible for clinical use

    The Founder’s Lecture 2009: advances in imaging of osteoporosis and osteoarthritis

    Get PDF
    The objective of this review article is to provide an update on new developments in imaging of osteoporosis and osteoarthritis over the past three decades. A literature review is presented that summarizes the highlights in the development of bone mineral density measurements, bone structure imaging, and vertebral fracture assessment in osteoporosis as well as MR-based semiquantitative assessment of osteoarthritis and quantitative cartilage matrix imaging. This review focuses on techniques that have impacted patient management and therapeutic decision making or that potentially will affect patient care in the near future. Results of pertinent studies are presented and used for illustration. In summary, novel developments have significantly impacted imaging of osteoporosis and osteoarthritis over the past three decades

    Magnetic Resonance Imaging of Articular Cartilage

    No full text

    In vivo quantification of human lumbar disc degeneration using T1ρ-weighted magnetic resonance imaging

    No full text
    Diagnostic methods and biomarkers of early disc degeneration are needed as emerging treatment technologies develop (e.g., nucleus replacement, total disc arthroplasty, cell therapy, growth factor therapy) to serve as an alternative to lumbar spine fusion in treatment of low back pain. We have recently demonstrated in cadaveric human discs an MR imaging and analysis technique, spin-lock T1ρ-weighted MRI, which may provide a quantitative, objective, and non-invasive assessment of disc degeneration. The goal of the present study was to assess the feasibility of using T1ρ MRI in vivo to detect intervertebral disc degeneration. We evaluated ten asymptomatic 40–60-year-old subjects. Each subject was imaged on a 1.5Β T whole-body clinical MR scanner. Mean T1ρ values from a circular region of interest in the center of the nucleus pulposus were calculated from maps generated from a series of T1ρ-weighted images. The degenerative grade of each lumbar disc was assessed from conventional T2-weighted images according to the Pfirmann classification system. The T1ρ relaxation correlated significantly with disc degeneration (r=βˆ’0.51, P<0.01) and the values were consistent with our previous cadaveric study, in which we demonstrated correlation between T1ρ and proteoglycan content. The technique allows for spatial measurements on a continuous rather than an integer-based scale, minimizes the potential for observer bias, has a greater dynamic range than T2-weighted imaging, and can be implemented on a 1.5Β T clinical scanner without significant hardware modifications. Thus, there is a strong potential to use T1ρ in vivo as a non-invasive biomarker of proteoglycan loss and early disc degeneration
    corecore